The September 2010 PIESA/Aerosol Experiments: Difference between revisions

Line 20: Line 20:


The FRP needed to calculate the biomass burning emission were derived from the MODIS Thermal Anomalies/Fire products (MOD14, MYD14). The calibration of the QFED emissions was done individually for the MODIS/Terra and MODIS/Aqua data using the emissions factors from Andreae and Merlet. Our first step was to use global monthly mean GFED emissions to find individual global calibration factors for MODIS/Terra and MODIS/Aqua instruments. Using individual calibration factors has an advantage over using a single common factor for the two instruments, because one can account for the differences in the fire strengths at the local time of the satellite overpass, and at the same time provides redundancy in case one of the satellites fails. The derived in this way fire emissions were used in the 'R_ddQFED' experiment (see below). The benefits of this calibration is that the globally the fire emissions are comparable to the commonly used GFED emissions, however they are available daily at 0.25x0.25 degrees horizontal resolution.
The FRP needed to calculate the biomass burning emission were derived from the MODIS Thermal Anomalies/Fire products (MOD14, MYD14). The calibration of the QFED emissions was done individually for the MODIS/Terra and MODIS/Aqua data using the emissions factors from Andreae and Merlet. Our first step was to use global monthly mean GFED emissions to find individual global calibration factors for MODIS/Terra and MODIS/Aqua instruments. Using individual calibration factors has an advantage over using a single common factor for the two instruments, because one can account for the differences in the fire strengths at the local time of the satellite overpass, and at the same time provides redundancy in case one of the satellites fails. The derived in this way fire emissions were used in the 'R_ddQFED' experiment (see below). The benefits of this calibration is that the globally the fire emissions are comparable to the commonly used GFED emissions, however they are available daily at 0.25x0.25 degrees horizontal resolution.
[[image: BB_freq-map.th_0.5.jas.png|thumb|Frequency of AOT_BB/AOT ratio exceeding 0.5 for JAS, 2004]]
[[image: BB_freq-map.th_0.8.jas.png|thumb|Frequency of AOT_BB/AOT ratio exceeding 0.8 for JAS, 2004]]


Our next objective was to produce more realistic fire emission magnitudes. As in-situ measurements of fire emissions are very limited, we instead relied on the fact that biomass burning can have significant contribution to the total aerosol loadings near active fires and downwind. Thus, one can use AOT magnitude and relate it to the fire emission strength.  
Our next objective was to produce more realistic fire emission magnitudes. As in-situ measurements of fire emissions are very limited, we instead relied on the fact that biomass burning can have significant contribution to the total aerosol loadings near active fires and downwind. Thus, one can use AOT magnitude and relate it to the fire emission strength.